ZRT-101 APC

REAL-TIME PCR SYSTEM

Get a Quote
Download Catalog

Description

THERMAL BLOCK

Specifications ZRT-101 APC
Sample Capacity(wells) 96
Reaction Volume 0-100μL
Consumables 0.2ml 96-well Plates (unskirt) ;
0.2ml 8-strip tubes , 0.2ml PCR single tube
(Optical flat cap, clear, frosted, white tube)
Temperature Range 0°C-100°C
Heating/Cooling Method Peltier
Max Heating Rate 6.1°C/sec
Average Heating Rate 4.5°C/sec
Max Cooling Rate 5.0°C/sec
Average Cooling Rate 2.8°C/sec
Temperature Accuracy ±0.1°C
Temperature Uniformity ±0.1°C
Gradient Range 1°C-40°C
Gradient Block 12 row
Special Temperature Protocol Gradient PCR
Long PCR
Touch Down PCR

HEAT LID

Specifications ZRT-101 APC
Temperature range Temperature-110°C

OPTICAL SYSTEM

Specifications ZRT-101 APC
Excitation Source 6 LEDs
Detector Photodiode
Detection Position Excitation and scan at top
Detection Method 6 channels scanning at the same time, no edge effect
Detection Time 7 seconds for 96 wells for all channels
Range of excitation/emission
wavelengths(nm)
1.465 /510 (FAM,SYBR Green I, SYT09, EvaGreen, LC Green)
2.527/ 563 (HEX, VIC, TET, JOE)
3.580 /616 (ROX, Texas Red)
4.632/ 664 (Cy5)
Probe Taqman Probe,
Molecular beacons probe,
Scorpion probe,
FRET
Multiplexing Up to 6 targets
Fluorescence Linearity r≥0.990
Fluorescence Dynamic Range Adjustable

PERFORMANCE

Specifications ZRT-101 APC
Sample Linearity r≥0.999
Sample Repeatability Ct value CV≤0.5%
Sample Dynamic Range 1-1010 copies
Data Analysis Modes Qualitative analysis, Absolute quantification, Relative quantification, Genotyping analysis,Endpoint analysis, Melt curve analysis, High Resolution Melting
Control Modes 1. 10.4’ touch screen
2. PC direct control
3. WLAN control (One PC can control max 10 units, and device
can be controlled by any PC in the WLAN)
Sample Drawer Touch screen command
Data Storage Upload and download through USB disk, 1000 results can be
stored in machine
Power Failure Protection Automatically start running experiments after power supply, no need wait PC software
Customize Report Templates reserved, report can customized
Administration Management Administrator can set functions limits for users
Transport Locker Automatically detect transport locker
Fault Management Fault report and analysis, solution instruction
LIS Connection CSV,Excel,TXT format data output, open port for LIS connection

OTHERS

Specifications ZRT-101 APC
PC operating system Win 7, Win 10
Communication Port 1 ethernet and 3 USB
Footprint (WxDxH) 355mm X 480mm X 485mm
Weight 30kg
Power usage AC 100 to 125 V / 200 to 240 V (50/60 Hz)
Power consumption 900VA
Work environment Temperature: 10°C – 30°C Humid