ZRT-100 APC
REAL-TIME PCR SYSTEM
Description
THERMAL BLOCK
Specifications | ZRT-100 APC |
---|---|
Sample Capacity(wells) | 96 |
Reaction Volume | 0-100μL |
Consumables | 0.2ml 96-well Plates (unskirt) ; 0.2ml 8-strip tubes , 0.2ml PCR single tube (Optical flat cap, clear, frosted, white tube) |
Temperature Range | 0°C-100°C |
Heating/Cooling Method | Peltier |
Max Heating Rate | 6.1°C/sec |
Average Heating Rate | 4.5°C/sec |
Max Cooling Rate | 5.0°C/sec |
Average Cooling Rate | 2.8°C/sec |
Temperature Accuracy | ±0.1°C |
Temperature Uniformity | ±0.1°C |
Gradient Range | 1°C-40°C |
Gradient Block | 12 row |
Special Temperature Protocol | Gradient PCR Long PCR Touch Down PCR |
HEAT LID
Specifications | ZRT-100 APC |
---|---|
Temperature range | Temperature-110°C |
OPTICAL SYSTEM
Specifications | ZRT-100 APC |
---|---|
Excitation Source | 4LEDs |
Detector | Photodiode |
Detection Position | Excitation and scan at top |
Detection Method | 6 channels scanning at the same time, no edge eect |
Detection Time | 7 seconds for 96 wells for all channels |
Range of excitation/emission wavelengths(nm) |
1.465 /510 (FAM,SYBR Green I, SYT09, EvaGreen, LC Green) 2.527/ 563 (HEX,VIC,TET,JOE) 3.580 /616 (ROX,Texas Red) 4.632/ 664 (Cy5) |
Probe | Taqman Probe, Molecular beacons probe, Scorpion probe |
Multiplexing | Up to 4 targets |
Fluorescence Linearity | r≥0.990 |
Fluorescence Dynamic Range | Adjustable |
PERFORMANCE
Specifications | ZRT-100 APC |
---|---|
Sample Linearity | r≥0.999 |
Sample Repeatability | Ct value CV≤0.5% |
Sample Dynamic Range | 1-1010 copies |
Data Analysis Modes | Qualitative analysis, Absolute quantification, Relative quantification, Genotyping analysis,Endpoint analysis, Melt curve analysis, High Resolution Melting |
Control Modes | 1. 10.4’ touch screen 2. PC direct control 3. WLAN control (One PC can control max 10 units, and device can be controlled by any PC in the WLAN) |
Sample Drawer | Touch screen command |
Data Storage | Upload and download through USB disk,1000 results can be stored in machine |
Power Failure Protection | Automatically start running experiments after power supply, no need wait PC software |
Customize Report | Templates reserved, report can customized |
Administration Management | Administrator can set functions limits for users |
Transport Locker | Automatically detect transport locker |
Fault Management | Fault report and analysis, solution instruction |
LIS Connection | CSV,Excel,TXT format data output, open port for LIS connection |
OTHERS
Specifications | ZRT-100 APC |
---|---|
PC operating system | Win 7, Win 10 |
Communication Port | 1 ethernet and 3 USB |
Footprint (WxDxH) | 355mm X 480mm X 485mm |
Weight | 30kg |
Power usage | AC 100 to 125 V / 200 to 240 V (50/60 Hz) |
Power consumption | 900VA |
Work environment | Temperature: 10°C – 30°C Humid |